...are installed . USB cable . Computer 1 . Place the units where desired , and connect the CAT5 extension link cabling to the link ports ( RJ - 45 ) on the Local Extender and the Remote Extender . Figure QS - 2 . Connecting the Local Extender to t...
...installed and used according to the instructions in this manual , together with the specified cables and the maximum cable length < 3m , the Units : ACS1009A - MM , ACS2209A - MM ACS4001A - MM , ACS4201A - MM ACS1009A - SM , ACS2209A - SM ACS4001...
...verify that the HDMI cable used is of high quality . This is particularly important for 4K 60 Hz , which requires a premium HDMI cable . 4.1.2.2 ASSIGNING A NEW SOURCE TO A SINGLE DECODER ( RX ) To assign a new source to a decoder ( RX ) , repeat...
...end of a DisplayPort cable to the DisplayPort port on the source device ( e.g . computer , server , or other IT device ) . Then connect the other end to the DP IN port located on the TX unit . 3 . Connect the DisplayPort display to the DP OUT por...
...that is , in strict accordance with the manufacturer’s instructions , may cause interference to radio communication . It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in S...
...DB9 RS - 232 to RJ - 45 cable , connect a terminal or terminal emulator to the Gigabit Managed Ethernet Switch to access the command - line interface . Attach the RJ - 45 serial port on the switch’s front panel to connect to the switch for conso...
...installed and used according to the instructions in this manual , together with the specified cables and the maximum cable length < 3m , the Units : ACS2009A - R2 - MM , ACS2009A - R2 - SM , ACS2209A - R2 - MM , ACS2209A - R2 - SM ACS4001A - R2 -...
...that is , in strict accordance with the manufacturer’s instructions , may cause interference to radio communication . It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Su...
...conne ia e 18 - S - cables Conve ector ± 10 % ensing ) 104 ° shipp then sis an ( LHC0 r Conver , Media enclo cm F TBA switch rTray befor onne equip ( - 20 ° ctor F on rter , lot , betw secu 1 H ed Po 1.5A ( 0 ° max . 18A - sure x ter 18 - S the ...
...Attach the power cable and , on AC power supplies , move the toggle switch to the ON position . When the unit is receiving power , the green PWR ( power ) LED will light . Black Box Customer Service Call : ( 724 ) 746 - 5500 Phone orders 24 h...